XDx34 Environmental and Power Usage
The XD234 and XD1034 are designed for sustained ambient temperatures between 0°C and 50°C, with transients up to 70°C (at 90% maximum relative humidity, non-condensing). Operating the players above 50°C ambient for prolonged periods may reduce the operational lifetime of the product.
Important
Exposing a cold player to warm air at high relative humidity may cause water to condense inside the player, leading to component failure. Damage due to such internal condensation is not covered by warranty. If a player is cold, allow several hours for it to acclimatize to ambient conditions before applying power.
The power supply for the XD234 and XD1034 is 36W (12V@3A). The device will use approximately 1A of power when playing a 4096x2160x60p H.265 (HEVC) source file.
An additional 2A of power is available for peripherals connected to the player. The user should not connect any combination of peripherals that will exceed 2A draw. If more than 2A is drawn, the external power supply may shut down due to over-current conditions. The unit will not be damaged, but it may reboot or not operate properly until the overload is removed.
If the device is being powered by the power supply, the 2A can be shared in any way among the following connectors:
Connector | Maximum Power Usage |
---|---|
RJ-45 | Approx. 180mA (when transferring data) |
USB 2.0 (Type C) | 1A |
USB 2.0 (Type A) | 1.5A |
GPIO 3.3V | 500mA |
HDMI® 5V | 70mA |
IR blaster output | 85mA |