Overview

BrightSign’s OS version 8.2.72 and BrightAuthor:connected version 1.6.29 contain a new feature that lets users see and modify settings using the BSN.cloud Properties Panel or through the BSN.cloud API. To avoid backwards compatibility issues, the supervisor won't honor these settings unless it is first enabled in your custom Device Setup Package, custom presentation, or custom application/plugin.

This feature is natively supported and enabled in BrightAuthor:connected presentations using version 1.6.29 or later, but you must enable it if you are running custom scripts. The steps required to enable this feature are described below.

Pre-Requisites

  • You must be using BSN.cloud

  • Minimum BrightAuthor:connected version: 1.6.29

  • Minimum OS version: OS 8.2.72


Panel
borderColor#3D3D3D
bgColor#F4F4F4
titleColor#3D3D3D
borderWidth0
titleBGColor#3D3D3D
borderStylesolid

ON THIS PAGE

Table of Contents
indent20px



Implementing the Settings Handler

To enable the Settings Handler from a custom Device Setup Package (not downloaded from BrightAuthor:connected):

  1. Include the code snippet from the Example Script section, below, in your Device Setup Package.
  2. In BrightAuthor:connected, navigate to the player’s network (under the Network tab on the top right). In this section, the player settings are available in the Properties panel.
  3. Note: The script type would be "Setup" if the “setup script” comment in the Example Script is initialized as “setup” in order to support settings being applied from BrightAuthor:connected after the setup process is completed. The setup process is completed after the success splash screen is displayed on the player’s video HDMI output (if you are using the BrightAuthor:connected setup package, not a custom setup script).

To enable the Settings Handler from a custom presentation or custom application/plugin, include either the Example Script code snippet in your custom application/plugin/presentation or attach it to the presentation.

Once the device-side API is turned on, the player settings will be accessible in the Properties panel of BrightAuthor:connected (under the Network tab).


API Specification

This API specification is used by custom setup package scripts, custom presentation, or plugins, either invoked by BrightScript or JavaScript, to enable the “Settings Panel” (settings handler).

The base URL or player’s IPv4 IP address (the default port server is hosted on 8000) is http://localhost


GET /api/v1/system/supervisor/capabilities

Request Body

Code Block
languagejs
{
	"script": {
	“type”: “Custom” // Either “Custom” or “Setup”,
	“version”: “10.0.60” // Can be any version in a x.x.x format. Used to communicate script version to BSN.cloud,
	displayed in “Settings Panel” }
}

Response Body

  • Success: {"success":true}

  • Error: {"status”: <error status code>, “message”: <error message>}


Example Script

Partners who want to upgrade to use this feature must include the following code snippet in their BrightScript application/plugin. 

Code Block
languagejs
localBaseUrl = "http://localhost" 
supervisorApiV1Route = "/api/v1"

supervisorCapabilitiesUrlXfer = CreateObject("roUrlTransfer") 
supervisorCapabilitiesUrlXfer$ = localBaseUrl + supervisorApiV1Route + "/system/supervisor/capabilities"
supervisorCapabilitiesUrlXfer.SetUrl(supervisorCapabilitiesUrlXfer$) 
supervisorCapabilitiesUrlXfer.SetTimeout(15000) 
supervisorCapabilitiesUrlXfer.SetProxyBypass(["127.0.0.1", "localhost"])
supervisorCapabilitiesUrlXfer.addHeader("Content-type", "application/json")

script = CreateObject("roAssociativeArray")
  
scriptType$ = "Custom" ' script type would be "Setup" if it is setup script
version$ = "10.0.60" ' current autorun script version

script.AddReplace("type", scriptType$) 
script.AddReplace("version", version$)

body = {} 
body.AddReplace("script", script)

stringifiedJson = FormatJson(body)
rc = supervisorCapabilitiesUrlXfer.PostFromString(stringifiedJson)

if rc = 200 then
	print "===settings handler enabled"
else
	print "===failed to start settings handler, error code:";rc
end if


Caveats

  • The settings handler can override custom settings applied by the setup script.

  • Edits to the property sheet settings in the interface will not be applied on the device side unless the code snippet above is added to the runtime application (not the setup application) or it is added as a plugin to the custom presentation (not the setup application).